- Swiss testing laboratory
Minimum Bactericidal Concentration (MBC)
Hassle-free testing experience
Need to get a product tested? No worries! To and fro logistics are on us; we collect your products, test them and, deliver them back to you.
Related tests for you
Qualitative assay to evaluate the susceptibility or resistance of pathogenic bacteria to antibacterial agents.
Determining lowest concentration of an antimicrobial agent that inhibits visible growth of a microorganism
Quick understanding of the test
Minimum Bactericidal Concentration
Application
- Serial dilutions of antimicrobial test compounds are made and are inoculated with test microorganisms.
- These dilutions are further transferred into 96-well Microtiter Plates. In parallel, a growth control and sterile control are also used in the test procedure.
- Microtiter plate is further incubated at a specific temperature and duration.
- After incubation bacterial growth is observed.
- The lowest concentration of dilution with no turbidity or visible growth is referred as MIC (Minimum Inhibitory Concentration).
- Dilutions showing MIC are plated on a suitable growth medium and incubated to determine the viable cells.
- Multiple antimicrobial agents can be evaluated against a wide range of microorganisms.
- The test provides actionable insights for reformulation or product efficacy enhancement.
Turnaround Time
Do you have a product that needs testing?
Abstract
The Minimum Bactericidal Concentration (MBC) test determines the lowest concentration of an antibacterial agent required to kill 99.9% of the original test microorganisms within a specified time frame. It is typically performed after establishing the Minimum Inhibitory Concentration (MIC). While the MIC identifies the lowest concentration that visibly inhibits microbial growth, the MBC demonstrates the lowest level of antimicrobial agent resulting in microbial death. This test is crucial in pharmaceutical development, clinical microbiology, and industrial applications, helping ensure that antimicrobial agents achieve effective bactericidal activity.
Minimum Bactericidal Concentration (MBC) Test Method
- Overnight grown culture of test microorganisms is diluted in growth-supporting broth (Mueller Hinton Broth) between 1 x 10^5 and 1 x 10^6 CFU/ml.
- Serial dilutions of antimicrobial test compounds are made.
- All the dilutions of test compounds are inoculated with an equal volume of test microorganisms.
- These dilutions are further transferred into 96-well Microtiter Plates. In parallel, a growth control (bacterial suspension without any antimicrobial agent) and sterile control (media without bacteria where no bacterial growth is observed after incubation) are also used in the test procedure.
- Microtiter plate is further incubated at a specific temperature and duration.
- After incubation bacterial growth is observed, turbidity indicates the growth of the microorganism, and lowest concentration of dilution with no turbidity or visible growth is referred as MIC (Minimum Inhibitory Concentration).
- 2-3 dilutions showing MIC are plated on a suitable growth medium and incubated to determine the viable cells.
- The lowest concentration that shows 99.9% reduction of the tested bacteria is MBC.
Importance of Minimum Bactericidal Concentration
- Therapeutic Guidance: It guides clinicians to use the appropriate dosages of antibiotics so that they could treat patients effectively without resistance.
- Research and Development: MBC is an integral part of drug development and will be used to evaluate the new antibiotics with well-established ones in terms of their potency.
- Infection Control: It will assist in formulating guidelines of disinfection and sterilization procedures in healthcare environments.
Strengths of Minimum Bactericidal Concentration (MBC)
- The MBC test helps in determining the minimum concentration of an agent required to achieve a bactericidal effect.
- The MBC test is an effective and relatively cost-efficient method for screening multiple antimicrobial agents for potency.
- The MBC test parameters are simple to control in a laboratory setting, enabling easy comparisons of various antimicrobial agents simultaneously.
- This method involves an extended contact time to make sure the anti-microbial agent really measures how much is needed to kill them.
- Knowing the MBC helps clinicians or product developers determine the concentration needed for full kill, not just inhibition.
- For sterilization, disinfectants, or bactericidal drugs, MBC gives stronger evidence of effectiveness than MIC alone.
Limitations of Minimum Bactericidal Concentration Test (MBC)
- An MBC must be determined separately for each microorganism, as different microbes often have varying MBC values for the same antimicrobial agent.
- MBC test results do not indicate the concentration required to disinfect or sanitize surfaces within short contact times, such as 10 minutes.
- Using highly nutritive growth media like Tryptic Soy Broth can interfere with accurate MBC results; therefore, Mueller-Hinton Broth is recommended for this method.
Advantages of Minimum Bactericidal Concentration Test (MBC)
- Differentiates Bacteriostatic from Bactericidal Agents:
It helps distinguish whether an agent inhibits bacterial growth or eradicates bacteria, providing critical insights for product development and clinical applications. - Standardized and Quantifiable Results:Offers consistent, reproducible results through standardized methodologies, ensuring reliability in research and clinical practice.
- Complements MIC Tests: MBC tests provide a more comprehensive understanding of the effects of antimicrobials, complementing MIC tests and offering a fuller picture of their pharmacodynamic properties.
Conclusion
At Microbe Investigations Switzerland (MIS), we offer comprehensive testing services including Minimum Bactericidal Concentration (MBC), Minimum Inhibitory Concentration (MIC), and Zone of Inhibition (ZOI) testing to accurately measure how effectively your products inhibit and kill harmful microorganisms.
Our detailed results help you validate product claims, meet regulatory requirements, and build trust with customers and stakeholders. Whether youโre developing new disinfectants, sanitizers, or antimicrobial coatings, MIS delivers precise, reliable data you can count on.
Get in touch with us today to learn more about our microbiological testing services or to request a quote
Frequently Asked Questions
DR. Martinoz Scholtz
The Minimum Bactericidal Concentration (MBC) test determines the minimum concentration of antibacterial agents required to kill 99.9% of test microorganisms in the original inoculum within a specified time frame
This test is applicable for drugs, antiseptics, disinfectants, and other liquid formulations.
The turnaround time for this test is 1-2 weeks .
At Microbe Investigations Switzerland, we test for MBC using the following bacteria: Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter species.
Minimum bactericidal concentration is the lowest concentration of an antibiotic at which bacteria are killed whereas minimum inhibitory concentration is the lowest concentration at which bacterial growth is inhibited.
Testing for Minimum Bactericidal Concentration (MBC) is crucial in clinical diagnostics so that proper dosing is prescribed, making the outcome of treatment effective in killing the pathogen and preventing resistance.
Meet the best of the blend of
R&D, Efficacy Testing,
Innovation and Passionate
Experts at MIS.
Explore More
Antibacterial testing of disinfectants plays
Antimicrobial testing is important to
Antibacterial efficacy testing is an
Letโs face it, we are