The growing demand for more effective disinfectants has necessitated the development of standardized testing protocols which are critical for the evaluation and validation of new and improved products for regulatory approval and market entry. Among them is AOAC 955.17 fungicidal disinfectant testing. This frequently used test assists the user in ascertaining if the disinfectant kills fungi and whether such products are effective in environments where strict sanitation is required such as healthcare facilities, food processing units and public spaces.

Here we will focus on the fundamental aspects of AOAC 955.17 which involves the steps and the need for fungicidal tests. We also elaborate on principal test parameters such as the microbiological test strains, the conditions like temperature, contact time and the area of application in which the test should be carried out. 

Understanding AOAC 955.17

What is AOAC 955.17?

AOAC 955.17 fungicidal disinfectant testing is the standardized test method developed to determine the fungicidal activity of a disinfectant. This test is altogether important when establishing the potential of given disinfectants to destroy fungal spores therefore establishing high sanitation. These methods are applied broadly to assess the effectiveness of disinfectants against a variety of fungi including Trichophyton mentagrophytes which is a pathogenic fungus that causes dermatophytosis or ringworm disease in humans and animals.

Why is Fungicidal Activity Testing Important?

Unlike bacteria, fungi have more resilient spore forms that can survive in extreme environments. As a result, their elimination needs to be done by using some specifically strong fungicidal disinfectants. Testing disinfectants’ fungicidal properties helps to ensure product’s efficacy and safety thus safeguarding public health, predominantly in the industrial domain where the likelihood of contamination is high.

For instance, fungi become invasive in a hospital setting and pose numerous nosocomial infections, which are serious threats to immunocompromised patients. These pathogens should be taken care of using a disinfectant which has been tested for its efficacy. Therefore, there is a need to evaluate disinfectants against such pathogens using AOAC 955.17 fungicidal disinfectant testing.

Key Test Parameters in AOAC 955.17

1. Test Strain

The AOAC 955.17 method employs a particularly resistant strain, Trichophyton mentagrophytes. A fungal strain as a test organism. This strain can produce spores and is resistant to destruction. A causative organism of athlete’s foot and ringworm among other diseases is a dermatophyte. Testing against this strain ensures that the disinfectant can eliminate fungal spores effectively.

2. Temperature

Temperature control is an important parameter in standardizing the experimental conditions in AOAC 955.17 fungicidal disinfectant testing. Most of the disinfectants are tested under a constant temperature using a circulating water bath. The purpose is to simulate the real conditions that are encountered with the field application of the disinfectant. The globally accepted range of temperature for disinfectant testing is 20-25°C. Proper measures are taken to ensure the performance and efficiency of the disinfectant are optimized, operational and effective.

3. Contact Time

Contact time significantly influences the disinfectant’s effectiveness. It has to be distinctly specified during the AOAC 955.17 test to show the fungicide’s ability to kill the fungal spores within the designated time. In most cases the contact time is set at between 5-10 minutes relative to the strength of the disinfectant and its application. The less the contact time of the disinfectant, the better its efficiency is. It is a prolific property in critical areas with an urgent need for sanitization​.

4. Scope of Application

AOAC 955.17 fungicidal disinfectant testing caters to industries ranging from healthcare facilities to food production areas. The testing involves disinfectants that are used in areas where fungal infection has serious health impacts.  The test ensures that the disinfectant is potent in killing fungi in various substrates such as medical devices, floors, walls and any other food contact surfaces. The versatility of the method allows it to be modified to meet the needs of specific research depending on the use of the disinfectant.

Procedure of AOAC 955.17

The AOAC 955.17 fungicidal disinfectant testing follows a systematic procedure to ensure accurate results:

  • Culturing the Fungal Strain: Spore suspension is prepared for a standard fungal strain such as Trichophyton mentagrophytes by culturing it under controlled conditions. The mycelium, the vegetative part of the fungus, must be generated in order for the fungus to produce spores.

  • Preparing Dilutions: Different dilutions of the disinfectant is prepared and each dilution is tested for its effectiveness in killing the fungi or retarding its growth. Test is done to determine the minimum concentration at which the spores of fungi remain sensitive to the disinfectant.

  • Temperature Control: The diluted disinfectant solutions are placed in a circulating water bath to bring the solution to the desired temperature. This step is crucial to maintain a constant environment for all concentrations during treatment and is a key feature in obtaining reproducible results for the AOAC 955.17 fungicidal disinfectant test.

  • Contact with Fungal Spores: An exact volume of the fungal spore suspension is transferred to each of the disinfectant’s dilutions and incubated usually from 5 to 10 minutes.

  • Neutralization and Incubation: After the contact time an aliquot of the suspension is transferred into a neutralizing growth medium that is assumed to stop the activity of the disinfectant. Then the samples are incubated under optimal conditions for the growth of fungi at about 20-25 °C.

  • Evaluation: After a period of 10 days the samples are evaluated to determine which dilutions of the disinfectant showed fungicidal activity. The highest dilution demonstrates the ability to neutralize the fungi. This is a critical point in AOAC 955.17 fungicidal disinfectant testing because it is recorded as the effective concentration for that disinfectant​.

This analytical procedure AOAC 955.17 is crucial in evaluating the fungicidal activity of disinfectants. It ensures the products applied in sensitive environments like hospitals, the food industry and public places indeed eradicate dangerous fungi. By testing disinfectants on a highly resistant fungal strain such as Trichophyton mentagrophytes under precisely controlled conditions, AOAC 955.17 helps manufacturing industries to develop effective disinfectants that can help maintain a high level of hygiene and safety.

If your company is seeking a reliable partner to assess the efficacy of your disinfectants, consider Microbe Investigations Switzerland MIS. Our competence lies in testing and validation services that assess whether your product conforms to all regulatory requirements and performs at its best in the field. Contact us to see how well you can assure the safety and effectiveness of your disinfectant products with AOAC 955.17 fungicidal disinfectant testing.

Contact us for more information



    SUBSCRIBE TO OUR BLOG POSTS

    Never miss a blog post from us. Subscribe Now!!



      Leaving Already?

      Did not find the information you were looking for or need something specific!


        Sign up with Us! Enter your email address for a 10% discount!